Semi-Circular Planetary Ball Mill
Get help choosing the configuration, supplied accessories and delivery basis. Not sure of the model? Start with your material and batch size.
Build a complete laboratory setup
Review the mill, sample-contact materials and trial conditions together.
Define the sample
Start with material properties, batch quantity and the measurement that will define a successful result.
Match the configuration
Check jar fit, media charge, electrical supply and any temperature or atmosphere requirements.
Plan the trial
Use a documented trial to compare particle size, sample recovery, temperature and wear.
Planetary Ball Mills
Semi-Circular Planetary Ball Mill
A vertical planetary mill for preparing small batches of powders and mixtures in the laboratory. The semi-circular design refers to the machine housing, not the shape of the grinding jars.
Fit for your experiment
Compare the XQM-A models by jar capacity and available bench space. Select jar and ball materials for the sample chemistry; vacuum processing requires a compatible sealed jar.
How to use this specification
The disc revolves while the grinding jars rotate about their own axes. Media impacts and friction act on the sample. Speed, duration, loading and jar material jointly influence the result.
Before selecting a configuration
- Define feed size, target particle size and acceptable wear contamination.
- Choose jar capacity from the working sample load, leaving room for media movement.
- Confirm balancing, clamping and any cooling or atmosphere option for the exact model.
Key features
- Four symmetric stations support parallel preparation of separate samples.
- Variable-frequency speed control, timed operation and alternating rotation support process development.
- The compact vertical layout suits laboratory batch preparation.
- Jar and media selection adapts the setup to different sample-contact requirements.
Construction details
- A semi-circular housing surrounds the vertical planetary assembly.
- The planetary disc is cast as an integral component.
- Precision gears transmit motion between the disc and jar stations.
- Dedicated jar clamps secure each vessel and allow removal between batches.
Configuration notes
Specify the required controller and sealed-jar accessories. A fine particle-size target needs a material-specific trial; it is not a guaranteed result for every sample.
Explore the construction details
See the arrangements described for this series. Photographs illustrate configurations; confirm the exact machine, controller, jars and supplied accessories in the quotation.

Integral planetary disc
The cast planetary disc carries the four jar stations. Match jar capacity and loaded mass to the selected model.

Precision gear transmission
The gear train transmits the planetary motion. This close-up illustrates the transmission component described for the series.

Four-station jar clamps
Dedicated clamps locate and secure the jars. Check vessel compatibility and clamping before each run.
Technical specifications
Compare the exact model and configuration. Nominal vessel volume is not the usable sample load. Particle-size results depend on the material and process; confirm critical values in the quotation.
| model | Specification | Can be equipped with ball mill tank Specification |
quantity | Can be equipped with vacuum tank Specification |
Equipment weight (kg) |
Equipment volume (mm) |
| XQM-0.4A | 0.4L | 25-100mL | 4 | Can be equipped with 50mL vacuum ball mill tank | 29 | 500×300×340 |
| XQM-1A | 1L | 50-500mL | 4 | Can be equipped with 50-250mL vacuum ball mill tank | 85 | 760×470×600 |
| XQM-2A | 2L | 50-500mL | 4 | Can be equipped with 50-250mL vacuum ball mill tank | 85 | 760×470×600 |
| XQM-4A | 4L | 250-1000mL | 4 | Can be equipped with 50-500mL vacuum ball mill tank | 85 | 760×470×600 |
| XQM-6A | 6L | 1-1.5L | 4 | Can be equipped with 50-1000mL vacuum ball mill tank | 85 | 760×470×600 |
| XQM-8A | 8L | 1-2L | 4 | Can be equipped with 50-1500mL vacuum ball mill tank | 150 | 880×560×642 |
| XQM-10A | 10L | 1-2.5L | 4 | Can be equipped with 1-2L vacuum ball mill tank | 150 | 880×560×642 |
| XQM-12A | 12L | 1-3L | 4 | Can be equipped with 1-2L vacuum ball mill tank | 150 | 880×560×642 |
| XQM-16A | 16L | 2-4L | 4 | Can be equipped with 1-3L vacuum ball mill tank | 205 | 950×600×710 |
| model | Device power supply | Power connector | Motor power (kW) | Speed regulation method | Run settings Total time(min) |
Alternate positive and negative Running time(min) |
Planetary disk speed (rpm) | Grinding tank speed (rpm) |
Speed ratio | Noise(dB) |
| XQM-0.4A | 220V 50Hz | single phase | 0.25kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-435 | 0-870 | 1:2 | 58±5 |
| XQM-1A | 220V 50Hz | single phase | 0.75kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-405 | 0-810 | 1:2 | 60±5 |
| XQM-2A | 220V 50Hz | single phase | 0.75kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-405 | 0-810 | 1:2 | 60±5 |
| XQM-4A | 220V 50Hz | single phase | 0.75kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-405 | 0-810 | 1:2 | 60±5 |
| XQM-6A | 220V 50Hz | single phase | 0.75kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-335 | 0-810 | 1:2 | 60±5 |
| XQM-8A | 220V 50Hz | single phase | 1.5kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-290 | 0-580 | 1:2 | 60±5 |
| XQM-10A | 220V 50Hz | single phase | 1.5kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-290 | 0-580 | 1:2 | 60±5 |
| XQM-12A | 220V 50Hz | single phase | 1.5kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-290 | 0-580 | 1:2 | 60±5 |
| XQM-16A | 380V 50Hz | Three phases | 3kW | Frequency conversion speed regulation | 1-9999 | 1-999 | 0-255 | 0-510 | 1:2 | 65±5 |
Product reference images



Plan a laboratory trial
Share the material, starting particle size, target result and batch quantity. Include the sample-contact materials and any temperature or atmosphere constraints.
Discuss this configuration → · Compare laboratory milling methods →
The trusted choice of industry leaders
Plan delivery around your configuration
Send the required quantity, destination and target arrival date with your inquiry. Compare the expected dispatch date separately from freight transit and import clearance.
| Order route | What needs to be confirmed | Scheduling starts when |
|---|---|---|
| Available stock | Exact model, jar/media set, electrical version and allocation of the unit. | The available configuration and order/payment requirements are confirmed; request the dispatch date for that unit. |
| Standard production | Model, quantity, supplied accessories and the current production slot. | The order specification and agreed payment requirements are complete and the production slot is confirmed. |
| Light customization | Changes such as contact materials, controls or electrical configuration, subject to technical review. | The changes are approved and any required components and production slot are confirmed. |
| Project customization | Technical scope, drawings where required, review milestones and acceptance requirements. | The technical scope is approved and agreed commercial and procurement prerequisites are met. |
Lead times are quoted for the confirmed configuration and current schedule. A catalog listing does not indicate live stock. Ask the quotation to state the lead-time range, its start condition and the agreed shipping basis.
Agree what arrives with the order
Confirm the machine or accessory quantity, jars and media, voltage/frequency, manuals, packing arrangement and required shipping documents in the quotation. Discuss inspection records or photographs needed before dispatch and the checks to make when receiving the shipment.
Delivery and handover details · See the manufacturing workshop
Know how support will work
Warranty and components
Our published service terms describe a one-year warranty and specified replacement conditions within the first month. Read the full warranty terms. Confirm coverage for the machine, motor/control components, jars, balls, liners and seals in the order; parts subject to wear need a separate coverage check.
Remote, spare-parts and on-site support
Contact TENCAN with the model, serial number and issue details for troubleshooting and parts identification. Provide your country and site location when asking about installation, training or on-site repair. Availability, travel, labor, freight and import costs must be agreed for the destination and service scope.
Check support responsibilities · Discuss your location and support needs
Review the evidence for your purchase
See the equipment being made
View workshop and assembly photographs, then discuss a visit or remote technical review for your project.
Evaluate your sample
Discuss sample grinding with the material, target result and permitted contact materials. Agree feasibility, sample quantity, test conditions and any charges before sending material.
Check documents and applications
Review available certificates for your exact model and destination, and application requirements relevant to your process.
FAQ
View moreGet In Touch
Our professional team will reply to you within one business day. Please feel free to contact us!
Share your material or application, quantity, destination and target purchase date. If a parameter is unknown, say so—we can help clarify it. Leave an email address or phone number so we can reply.
LABORATORY BALL MILLS