TENCAN · Laboratory grinding & sample preparation
LABORATORY BALL MILLSTalk to a milling specialistlichang0516@gmail.com
Direct from the manufacturerMill, jar & media matchingSample grinding supportApplication-based selection

Build a complete laboratory setup

Review the mill, sample-contact materials and trial conditions together.

01

Define the sample

Start with material properties, batch quantity and the measurement that will define a successful result.

02

Match the configuration

Check jar fit, media charge, electrical supply and any temperature or atmosphere requirements.

03

Plan the trial

Use a documented trial to compare particle size, sample recovery, temperature and wear.

Planetary Ball Mills

Semi-Circular Planetary Ball Mill

A vertical planetary mill for preparing small batches of powders and mixtures in the laboratory. The semi-circular design refers to the machine housing, not the shape of the grinding jars.

Fit for your experiment

Compare the XQM-A models by jar capacity and available bench space. Select jar and ball materials for the sample chemistry; vacuum processing requires a compatible sealed jar.

How to use this specification

The disc revolves while the grinding jars rotate about their own axes. Media impacts and friction act on the sample. Speed, duration, loading and jar material jointly influence the result.

Before selecting a configuration

  • Define feed size, target particle size and acceptable wear contamination.
  • Choose jar capacity from the working sample load, leaving room for media movement.
  • Confirm balancing, clamping and any cooling or atmosphere option for the exact model.

Key features

  • Four symmetric stations support parallel preparation of separate samples.
  • Variable-frequency speed control, timed operation and alternating rotation support process development.
  • The compact vertical layout suits laboratory batch preparation.
  • Jar and media selection adapts the setup to different sample-contact requirements.

Construction details

  • A semi-circular housing surrounds the vertical planetary assembly.
  • The planetary disc is cast as an integral component.
  • Precision gears transmit motion between the disc and jar stations.
  • Dedicated jar clamps secure each vessel and allow removal between batches.

Configuration notes

Specify the required controller and sealed-jar accessories. A fine particle-size target needs a material-specific trial; it is not a guaranteed result for every sample.

How do planetary mill layouts and controls differ?

Explore the construction details

See the arrangements described for this series. Photographs illustrate configurations; confirm the exact machine, controller, jars and supplied accessories in the quotation.

Integral planetary disc for Semi-Circular Planetary Ball Mill

Integral planetary disc

The cast planetary disc carries the four jar stations. Match jar capacity and loaded mass to the selected model.

Precision gear transmission for Semi-Circular Planetary Ball Mill

Precision gear transmission

The gear train transmits the planetary motion. This close-up illustrates the transmission component described for the series.

Four-station jar clamps for Semi-Circular Planetary Ball Mill

Four-station jar clamps

Dedicated clamps locate and secure the jars. Check vessel compatibility and clamping before each run.

Technical specifications

Compare the exact model and configuration. Nominal vessel volume is not the usable sample load. Particle-size results depend on the material and process; confirm critical values in the quotation.

model Specification Can be equipped with ball mill tank
Specification
quantity Can be equipped with vacuum tank
Specification
Equipment weight
(kg)
Equipment volume
(mm)
XQM-0.4A 0.4L 25-100mL 4 Can be equipped with 50mL vacuum ball mill tank 29 500×300×340
XQM-1A 1L 50-500mL 4 Can be equipped with 50-250mL vacuum ball mill tank 85 760×470×600
XQM-2A 2L 50-500mL 4 Can be equipped with 50-250mL vacuum ball mill tank 85 760×470×600
XQM-4A 4L 250-1000mL 4 Can be equipped with 50-500mL vacuum ball mill tank 85 760×470×600
XQM-6A 6L 1-1.5L 4 Can be equipped with 50-1000mL vacuum ball mill tank 85 760×470×600
XQM-8A 8L 1-2L 4 Can be equipped with 50-1500mL vacuum ball mill tank 150 880×560×642
XQM-10A 10L 1-2.5L 4 Can be equipped with 1-2L vacuum ball mill tank 150 880×560×642
XQM-12A 12L 1-3L 4 Can be equipped with 1-2L vacuum ball mill tank 150 880×560×642
XQM-16A 16L 2-4L 4 Can be equipped with 1-3L vacuum ball mill tank 205 950×600×710
model Device power supply Power connector Motor power (kW) Speed ​​regulation method Run settings
Total time(min)
Alternate positive and negative
Running time(min)
Planetary disk speed (rpm) Grinding tank speed
(rpm)
Speed ​​ratio Noise(dB)
XQM-0.4A 220V 50Hz single phase 0.25kW Frequency conversion speed regulation 1-9999 1-999 0-435 0-870 1:2 58±5
XQM-1A 220V 50Hz single phase 0.75kW Frequency conversion speed regulation 1-9999 1-999 0-405 0-810 1:2 60±5
XQM-2A 220V 50Hz single phase 0.75kW Frequency conversion speed regulation 1-9999 1-999 0-405 0-810 1:2 60±5
XQM-4A 220V 50Hz single phase 0.75kW Frequency conversion speed regulation 1-9999 1-999 0-405 0-810 1:2 60±5
XQM-6A 220V 50Hz single phase 0.75kW Frequency conversion speed regulation 1-9999 1-999 0-335 0-810 1:2 60±5
XQM-8A 220V 50Hz single phase 1.5kW Frequency conversion speed regulation 1-9999 1-999 0-290 0-580 1:2 60±5
XQM-10A 220V 50Hz single phase 1.5kW Frequency conversion speed regulation 1-9999 1-999 0-290 0-580 1:2 60±5
XQM-12A 220V 50Hz single phase 1.5kW Frequency conversion speed regulation 1-9999 1-999 0-290 0-580 1:2 60±5
XQM-16A 380V 50Hz Three phases 3kW Frequency conversion speed regulation 1-9999 1-999 0-255 0-510 1:2 65±5

Product reference images

Plan a laboratory trial

Share the material, starting particle size, target result and batch quantity. Include the sample-contact materials and any temperature or atmosphere constraints.

Discuss this configuration → · Compare laboratory milling methods →

The trusted choice of industry leaders

The trusted choice of industry leaders

Plan delivery around your configuration

Send the required quantity, destination and target arrival date with your inquiry. Compare the expected dispatch date separately from freight transit and import clearance.

Order routeWhat needs to be confirmedScheduling starts when
Available stockExact model, jar/media set, electrical version and allocation of the unit.The available configuration and order/payment requirements are confirmed; request the dispatch date for that unit.
Standard productionModel, quantity, supplied accessories and the current production slot.The order specification and agreed payment requirements are complete and the production slot is confirmed.
Light customizationChanges such as contact materials, controls or electrical configuration, subject to technical review.The changes are approved and any required components and production slot are confirmed.
Project customizationTechnical scope, drawings where required, review milestones and acceptance requirements.The technical scope is approved and agreed commercial and procurement prerequisites are met.

Lead times are quoted for the confirmed configuration and current schedule. A catalog listing does not indicate live stock. Ask the quotation to state the lead-time range, its start condition and the agreed shipping basis.

Agree what arrives with the order

Confirm the machine or accessory quantity, jars and media, voltage/frequency, manuals, packing arrangement and required shipping documents in the quotation. Discuss inspection records or photographs needed before dispatch and the checks to make when receiving the shipment.

Delivery and handover details · See the manufacturing workshop

Know how support will work

Warranty and components

Our published service terms describe a one-year warranty and specified replacement conditions within the first month. Read the full warranty terms. Confirm coverage for the machine, motor/control components, jars, balls, liners and seals in the order; parts subject to wear need a separate coverage check.

Remote, spare-parts and on-site support

Contact TENCAN with the model, serial number and issue details for troubleshooting and parts identification. Provide your country and site location when asking about installation, training or on-site repair. Availability, travel, labor, freight and import costs must be agreed for the destination and service scope.

Check support responsibilities · Discuss your location and support needs

Review the evidence for your purchase

See the equipment being made

View workshop and assembly photographs, then discuss a visit or remote technical review for your project.

Evaluate your sample

Discuss sample grinding with the material, target result and permitted contact materials. Agree feasibility, sample quantity, test conditions and any charges before sending material.

Check documents and applications

Review available certificates for your exact model and destination, and application requirements relevant to your process.

  • A semi-circular or square housing describes the machine body.

    Read more
  • The laboratory stirred mill uses manual lifting for vessel access.

    Read more
  • Two rollers support and rotate the jar or drum.

    Read more

Get In Touch

Our professional team will reply to you within one business day. Please feel free to contact us!

Share your material or application, quantity, destination and target purchase date. If a parameter is unknown, say so—we can help clarify it. Leave an email address or phone number so we can reply.

Your inquiry starts a configuration discussion. Ask for a recommendation, quotation with delivery conditions, or a sample-test review. Privacy information

Related Articles

Contact our team