Dual Planetary Ball Mill
Get help choosing the configuration, supplied accessories and delivery basis. Not sure of the model? Start with your material and batch size.
Build a complete laboratory setup
Review the mill, sample-contact materials and trial conditions together.
Define the sample
Start with material properties, batch quantity and the measurement that will define a successful result.
Match the configuration
Check jar fit, media charge, electrical supply and any temperature or atmosphere requirements.
Plan the trial
Use a documented trial to compare particle size, sample recovery, temperature and wear.
Planetary Ball Mills
Dual Planetary Ball Mill
The SXQM uses an additional planetary stage: a main disc drives smaller planetary assemblies. This changes the motion and energy input of the jars relative to a conventional planetary arrangement.
Fit for your experiment
Consider it for experiments that require a different milling intensity. Increased energy input also changes heating and wear, so assess temperature and contamination alongside particle size.
How to use this specification
The disc revolves while the grinding jars rotate about their own axes. Media impacts and friction act on the sample. Speed, duration, loading and jar material jointly influence the result.
Before selecting a configuration
- Define feed size, target particle size and acceptable wear contamination.
- Choose jar capacity from the working sample load, leaving room for media movement.
- Confirm balancing, clamping and any cooling or atmosphere option for the exact model.
Key features
- Compound motion from main and subsidiary discs increases the range of media movement.
- Media impacts, friction and shear act together on the sample.
- Four jars support parallel experimental batches.
- Variable speed, timing and direction reversal support process development.
Construction details
- A main planetary disc carries two subsidiary disc groups.
- Precision gears transmit the multiple stages of planetary motion.
- A reinforced welded frame supports the assembly.
- A variable-frequency controller sets the operating schedule.
Configuration notes
Match jar capacity, media charge and balancing to the selected model. Evaluate the target fineness on the actual material instead of treating the source particle-size claim as a universal specification.
Technical specifications
Compare the exact model and configuration. Nominal vessel volume is not the usable sample load. Particle-size results depend on the material and process; confirm critical values in the quotation.
| model | Specification | Can be equipped with ball mill tank specifications | quantity | Remark |
|---|---|---|---|---|
| SXQM-0.4 | 0.4L | 50-100ml | 4 | Can be equipped with 50ml vacuum ball mill tank |
| SXQM-1 | 1L | 250ml | 4 | Can be equipped with 50-100ml vacuum ball mill tank |
| SXQM-2 | 2L | 500ml | 4 | Can be equipped with 50-250ml vacuum ball mill tank |
| SXQM-4 | 4L | 1000ml | 4 | Can be equipped with 50-1000ml vacuum ball mill tank |
| SXQM-6 | 6L | 1500ml | 4 | Can be equipped with 50-1000ml vacuum ball mill tank |
| model | Device power supply | Motor power (kW) | Total running time (min) | Alternating forward and reverse running time (min) | Revolution (rpm) | Rotation(rpm) | Noise(dB) |
|---|---|---|---|---|---|---|---|
| SXQM-0.4 | 220V-50Hz | 0.75 | 1-9999 | 1-999 | 70-560 | 140-1120 | 58±5 |
| SXQM-1 | 220V-50Hz | 0.75 | 1-9999 | 1-999 | 70-560 | 140-1120 | 60±5 |
| SXQM-2 | 220V-50Hz | 0.75 | 1-9999 | 1-999 | 70-560 | 140-1120 | 60±5 |
| SXQM-4 | 220V-50Hz | 0.75 | 1-9999 | 1-999 | 70-560 | 140-1120 | 60±5 |
| SXQM-6 | 220V-50Hz | 0.75 | 1-9999 | 1-999 | 70-560 | 140-1120 | 60±5 |
| model | Motor power (kW) | Speed regulation method | Equipment weight (kg) | Equipment volume (mm) |
|---|---|---|---|---|
| SXQM-0.4 | 0.75 | Frequency conversion speed regulation | 250 | 1150×800×760 |
| SXQM-1 | 0.75 | Frequency conversion speed regulation | 250 | 1150×800×760 |
| SXQM-2 | 0.75 | Frequency conversion speed regulation | 250 | 1150×800×760 |
| SXQM-4 | 0.75 | Frequency conversion speed regulation | 250 | 1150×800×760 |
| SXQM-6 | 0.75 | Frequency conversion speed regulation | 250 | 1150×800×760 |
Product reference images

Plan a laboratory trial
Share the material, starting particle size, target result and batch quantity. Include the sample-contact materials and any temperature or atmosphere constraints.
Discuss this configuration → · Compare laboratory milling methods →
The trusted choice of industry leaders
Plan delivery around your configuration
Send the required quantity, destination and target arrival date with your inquiry. Compare the expected dispatch date separately from freight transit and import clearance.
| Order route | What needs to be confirmed | Scheduling starts when |
|---|---|---|
| Available stock | Exact model, jar/media set, electrical version and allocation of the unit. | The available configuration and order/payment requirements are confirmed; request the dispatch date for that unit. |
| Standard production | Model, quantity, supplied accessories and the current production slot. | The order specification and agreed payment requirements are complete and the production slot is confirmed. |
| Light customization | Changes such as contact materials, controls or electrical configuration, subject to technical review. | The changes are approved and any required components and production slot are confirmed. |
| Project customization | Technical scope, drawings where required, review milestones and acceptance requirements. | The technical scope is approved and agreed commercial and procurement prerequisites are met. |
Lead times are quoted for the confirmed configuration and current schedule. A catalog listing does not indicate live stock. Ask the quotation to state the lead-time range, its start condition and the agreed shipping basis.
Agree what arrives with the order
Confirm the machine or accessory quantity, jars and media, voltage/frequency, manuals, packing arrangement and required shipping documents in the quotation. Discuss inspection records or photographs needed before dispatch and the checks to make when receiving the shipment.
Delivery and handover details · See the manufacturing workshop
Know how support will work
Warranty and components
Our published service terms describe a one-year warranty and specified replacement conditions within the first month. Read the full warranty terms. Confirm coverage for the machine, motor/control components, jars, balls, liners and seals in the order; parts subject to wear need a separate coverage check.
Remote, spare-parts and on-site support
Contact TENCAN with the model, serial number and issue details for troubleshooting and parts identification. Provide your country and site location when asking about installation, training or on-site repair. Availability, travel, labor, freight and import costs must be agreed for the destination and service scope.
Check support responsibilities · Discuss your location and support needs
Review the evidence for your purchase
See the equipment being made
View workshop and assembly photographs, then discuss a visit or remote technical review for your project.
Evaluate your sample
Discuss sample grinding with the material, target result and permitted contact materials. Agree feasibility, sample quantity, test conditions and any charges before sending material.
Check documents and applications
Review available certificates for your exact model and destination, and application requirements relevant to your process.
FAQ
View moreGet In Touch
Our professional team will reply to you within one business day. Please feel free to contact us!
Share your material or application, quantity, destination and target purchase date. If a parameter is unknown, say so—we can help clarify it. Leave an email address or phone number so we can reply.
LABORATORY BALL MILLS