Light-Duty Horizontal Planetary Ball Mill
The WXQM light-duty design mounts grinding jars horizontally on a vertical planetary disc. The changing jar orientation redistributes the media and sample during the milling cycle.
Fit for your experiment
A candidate for small-batch studies where material collects at the base of a vertical jar. Confirm the permitted jar mass and loaded weight before choosing dense media.
How to use this specification
The disc revolves while the grinding jars rotate about their own axes. Media impacts and friction act on the sample. Speed, duration, loading and jar material jointly influence the result.
Before selecting a configuration
- Define feed size, target particle size and acceptable wear contamination.
- Choose jar capacity from the working sample load, leaving room for media movement.
- Confirm balancing, clamping and any cooling or atmosphere option for the exact model.
Key features
- Horizontal jar orientation helps redistribute samples that tend to settle.
- Four stations support parallel small-batch experiments.
- Different compatible jar sizes and materials allow changes in formulation.
- Variable-frequency control supports timed milling and alternating directions.
Construction details
- A vertical planetary disc carries horizontally mounted jars.
- The symmetric station layout supports a balanced load arrangement.
- Precision gears transmit the compound motion.
- Dedicated clamps provide access for jar installation and removal.
Configuration notes
A PLC touchscreen with timing and power-interruption memory is an optional controller configuration. Confirm the fitted controls and jar set for the selected machine.
Explore the construction details
See the arrangements described for this series. Photographs illustrate configurations; confirm the exact machine, controller, jars and supplied accessories in the quotation.

Horizontal jar arrangement
A vertical planetary disc carries horizontally mounted jars. This layout changes the direction in which the charge moves during milling.

Dedicated jar clamps
The holding arrangement secures the horizontally mounted vessels. Check jar dimensions, loaded mass and the required balance.

Controller configuration
The panel shown is a controller example. Touchscreen, timing and power-interruption functions depend on the control package selected for the order.

Precision gear transmission
Precision gears transmit the compound milling motion. The detail photograph illustrates the transmission described for this series.
Technical specifications
Compare the exact model and configuration. Nominal vessel volume is not the usable sample load. Particle-size results depend on the material and process; confirm critical values in the quotation.
| model | Drag ratio (rpm) | Grinding tank rotation speed (mm) | Inner diameter of grinding pot seat (mm) | Motor power | Grinding jar revolution diameter (mm) | Overall dimensions (mm) | Net weight(kg) |
|---|---|---|---|---|---|---|---|
| WXQM-(2-6) | 0.134 | 0~670 | 134 | 0.75KW | F234 | 700×560×530 | 96 |
| WXQM-(2-6)(H) | 0.134 | 0~670 | 134 | 1.5KW | F234 | 1220×620×810 | 266 |
| WXQM-(8-12) | 0.116 | 0~580 | 162 | 1.5KW | Φ275 | 1360×670×920 | 380 |
| WXQM-16 | 0.096 | 0~480 | 182 | 3KW | F385 | 1640×840×1040 | 470 |
| WXQM-20 | 0.086 | 0~430 | 200 | 4KW | F385 | 1640×840×1040 | 730 |
| WXQM-40 | 0.086 | 0~430 | 250 | 5.5KW | Φ430 | 1780×860×1070 | 790 |
| WXQM-60 | 0.062 | 0~310(1:1.5) | 275 | 7.5KW | Φ490 | 1980×1050×1220 | 1070 |
| WXQM-100 | 0.058 | 0~290(1:1.5) | 328 | 11kW | F578 | 2110×1150×1370 | 1210 |
Product reference images




Plan a laboratory trial
Share the material, starting particle size, target result and batch quantity. Include the sample-contact materials and any temperature or atmosphere constraints.
Discuss this configuration → · Compare laboratory milling methods →
The trusted choice of industry leaders
Plan delivery around your configuration
Send the required quantity, destination and target arrival date with your inquiry. Compare the expected dispatch date separately from freight transit and import clearance.
| Order route | What needs to be confirmed | Scheduling starts when |
|---|---|---|
| Available stock | Exact model, jar/media set, electrical version and allocation of the unit. | The available configuration and order/payment requirements are confirmed; request the dispatch date for that unit. |
| Standard production | Model, quantity, supplied accessories and the current production slot. | The order specification and agreed payment requirements are complete and the production slot is confirmed. |
| Light customization | Changes such as contact materials, controls or electrical configuration, subject to technical review. | The changes are approved and any required components and production slot are confirmed. |
| Project customization | Technical scope, drawings where required, review milestones and acceptance requirements. | The technical scope is approved and agreed commercial and procurement prerequisites are met. |
Lead times are quoted for the confirmed configuration and current schedule. A catalog listing does not indicate live stock. Ask the quotation to state the lead-time range, its start condition and the agreed shipping basis.
Agree what arrives with the order
Confirm the machine or accessory quantity, jars and media, voltage/frequency, manuals, packing arrangement and required shipping documents in the quotation. Discuss inspection records or photographs needed before dispatch and the checks to make when receiving the shipment.
Delivery and handover details · See the manufacturing workshop
Know how support will work
Warranty and components
Our published service terms describe a one-year warranty and specified replacement conditions within the first month. Read the full warranty terms. Confirm coverage for the machine, motor/control components, jars, balls, liners and seals in the order; parts subject to wear need a separate coverage check.
Remote, spare-parts and on-site support
Contact TENCAN with the model, serial number and issue details for troubleshooting and parts identification. Provide your country and site location when asking about installation, training or on-site repair. Availability, travel, labor, freight and import costs must be agreed for the destination and service scope.
Check support responsibilities · Discuss your location and support needs
Review the evidence for your purchase
See the equipment being made
View workshop and assembly photographs, then discuss a visit or remote technical review for your project.
Evaluate your sample
Discuss sample grinding with the material, target result and permitted contact materials. Agree feasibility, sample quantity, test conditions and any charges before sending material.
Check documents and applications
Review available certificates for your exact model and destination, and application requirements relevant to your process.
FAQ
View moreGet In Touch
Our professional team will reply to you within one business day. Please feel free to contact us!
Share your material or application, quantity, destination and target purchase date. If a parameter is unknown, say so—we can help clarify it. Leave an email address or phone number so we can reply.
LABORATORY BALL MILLS